Micromeritics ASAP® 2050 Xtended Pressure Sorption Analyzer is an easy-to-use instrument capable of collecting high-resolution, high-pressure adsorptive isotherms from vacuum to 10 atmospheres. While retaining many design elements of the popular ASAP 2020, the ASAP 2050 offers an extended range of capabilities that enables the instrument to obtain data in an elevated-pressure environment. The instrument also allows the user to collect traditional isotherms for determining surface area and porosity
ASAP 2020 Chemi Table of Contents Nov 03 i TABLE OF CONTENTS 1. GENERAL INFORMATION Organization of the Manual.
- ASAP 2020 Software Features The easy-to-use ASAP 2020 software utilizes a Windows interface that includes Wizards and applications to help plan, launch, and control the analysis. You can collect, organize, archive and reduce raw data, and store standardized sample infor-mation and analysis conditions for easy access during later applications.
- The Micromeritics ASAP 2020 Plus integrates a variety of automated gas sorption techniques into a single, but powerful, table top-instrument. The system is designed to provide high-quality surface area, porosity, chemisorption and physisorption isotherm data to materials analysis laboratories with ever-expanding analytical requirements.
- SOPHISTICATED DESIGN, INTUITIVE. OPERATION, RESEARCH-GRADE RESULTS ASAP® 2020 Plus: Accelerated Surface Area and Porosimetry System The Micromeritics ASAP 2020 Plus integrates a variety of automated gas sorption techniques into a single, but powerful, table top instrument.
The performance of the metal hydride is characterized by its hydrogen storage capacity (adsorption) and subsequent release (desorption) of hydrogen. The adsorption capacity of alkaline-exchanged zeolites is a key parameter for the design and optimization of pressure swing adsorption processes. The active surface area and porous structure of catalysts have a great influence on production rates. The ASAP 2050 is also useful in generating surface area and porosity data for materials such as nanotubes, activated carbons, and ceramics.
Features
Standard ASAP Features- Two independent vacuum systems allowing simultaneous automated preparation of two samples and analysis of another
- A highly flexible and interactive reporting system that includes an extremely versatile graphic user interface allowing custom presentation of results
- An optional chiller Dewar and recirculating bath allow the ASAP 2050 to be operated indefinitely – the instrument also supports the use of a standard Dewar with cryogen (typically liquid nitrogen or argon) that will provide at least 50 hours of unattended analysis without refilling the Dewar
- Straight-walled, stainless-steel sample tubes are capable of safe operation up to 150 psia
- Rapid collection of non-monotonic isotherms with standard isotherm cycling software
- Special degas heating mantles can be used to prepare samples in situ on the analysis port prior to analysis
- Temperatures at each degas port, and the rate of temperature change, can be set and monitored individually from a few degrees above ambient to 450 oC
- A user specified pressure setting protects the sample from steaming or damage during sample preparation
The ASAP 2050 includes powerful data reduction software to provide a variety of easy-to-interpret report options. This allows tremendous flexibility in the selection of analysis constants to best fit your specific application. All ASAP models have the capability to collect data over a prescribed segment of the pressure range, or to perform adsorption and desorption analyses over the entire pressure range, providing extensive surface area and porosity information.
- Repetitive Isotherm Cycling
- Single- and Multipoint BET (Brunauer, Emmett, and Teller) surface area
- Langmuir surface area
- Temkin and Freundlich isotherm analyses
- Pore volume and pore area distributions in the mesopore and macropore ranges by the BJH (Barrett, Joyner, and Halenda) method using a variety of thickness equations including user-defined, standard isotherm
- Pore volume and total pore volume in a user-defined pore size range
- F-Ratio plots that illustrate the difference between theoretical and experimental isotherm data
- Heat of Adsorption
Product Categories
Overview
ASAP 2020 Plus
Accelerated Surface Area and Porosimetry System
Sophisticated Design, Intuitive Operation, Research-Grade Results
The Micromeritics ASAP 2020 Plus integrates a variety of automated gas sorption techniques into a single, but powerful, table-top instrument. The system is designed to provide high-quality surface area, porosity, chemisorption and physisorption isotherm data to materials analysis laboratories with ever-expanding analytical requirements. | The ASAP 2020 Plus provides maximum versatility over a remarkable range of applications to meet your specific needs. With more installed instruments in more countries for more users, the ASAP family of products have proven to be the instruments of choice worldwide when researchers require precise, high-quality gas adsorption data. |
Features
Advanced Capabilities through Optional Configurations
The ASAP 2020 Plus can be configured to your specific needs with the option of upgrading at a later date as your analytical requirements change, maximizing the utility of this instrument and your investment.
Choose from low surface area, to heated vapor, to micropore capability. Add a cryostat, an external detector, or configure the unit for enhanced chemical resistance when working with aggressive vapors. The ASAP 2020 Plus permits one instrument to accommodate almost any surface characterization need in your lab.
Micromeritics Asap 2020 Software Free
Unique and Innovative Isothermal Jacket Cold Zone Control
Isothermal jackets are guaranteed for the life of the instrument and ensure a constant thermal profile along the full length of both the sample and saturation pressure (P°) tubes.
Design Versatility
Two independent vacuum systems permit simultaneous preparation of two samples while analyzing another. This maximizes your personnel productivity and your return on time invested
Continuous saturation pressure (P°) monitoring and unique Isothermal Jacket Cold Zone Control provide a stable thermal environment for both saturation pressure and adsorption. Spend time on results instead of controlling temperature variations
The ASAP 2020 Plus is configurable with many optional accessories to meet your specific analytical requirements
ASAP 2020 PLUS PHYSISORPTION
Research grade results in a customer-configurable instrument to meet a wide variety of applications for mesopore, micropore, and low surface area applications
Micromeritics Asap 2020 Software Download
- Programmable two-station degas system
for automated SOP sample preparation - A dedicated P° sensor allows for a faster analysis and provides P° values at the same conditions as the adsorption measurement
- Six analysis gas inlets with dedicated
vapor and helium free-space ports provide
greater flexibility and automated selection
of pretreatment, backfill, and analysis gases - Proven Isothermal Jacket Cold Zone
Control provides accurate, reproducible temperature maintenance - Long duration and refillable dewar provides virtually unlimited time-of-analysis capability
- Standard, independent dual vacuum systems (one for analysis, one for sample pretreatment). Also available is an optional, oil-free system
- Proprietary transducer system provides unequalled stability, fast response, and low hysteresis for improved accuracy and signal to noise improvement
- Coated monolithic, temperature-controlled, stainless-steel manifold provides non-contaminating, inert surface areas
MicroActive for ASAP 2020 Plus
Interactive Data Reduction Software
Micromeritics’ innovative MicroActive software allows you to interactively evaluate isotherm data. You can easily include or exclude data, fitting the desired range of experimentally acquired data points using interactive, movable calculation bars. The isotherm can be viewed real-time on either a linear or logarithmic scale, available to you under each calculation model
Physisorption Reports
- Isotherm
- BET Surface Area
- Langmuir Surface Area
- t-Plot
- Alpha-S Method
- BJH Adsorption and Desorption
- Dollimore-Heal Adsorption and Desorption
- Temkin and Freundlich
- Horvath-Kawazoe
- MP-Method
- DFT Pore Size and Surface Energy
- Dubinin-Radushkevich
- Dubinin-Astakhov
- User Defined Reports
Reduction Features
|
|
Optional Cryostat
A single-stage cryogenic refrigerator that operates on the Gifford-McMahon refrigeration cycle. It uses helium gas from a helium compressor(s) to offer a wide range of analytical temperatures with milli Kelvin levels of stability
Partnership and Support Network
- Expertise in application assistance is only a phone call away. Every Micromeritics instrument is backed by a dedicated, knowledgeable staff of experts
- Responsive worldwide service and technical support provides the needed security and peace of mind for you, our customers, ensuring that your sample and product development pathways continue to progress
- Referenced in an extensive number of peer-reviewed articles in prestigious journals, your ASAP 2020 will link you to a large and growing community of users
Micromeritics Asap 2020 Software Download
Specifications:
Micromeritics Asap 2020 Software
Pressure Measurement: 0 to 950 mmHg Resolution:Up to 1 x 10-7 torr (0.1 mmHg transducer) Accuracy:> 0.15% of reading | Degas System:Ambient to 450 °C, 1 °C increments System Capacity: 1 analysis, 2 degas ports Cryogen System:3 L, > 72 hr. dewar, unlimited time with refilling during analysis | Stable Cold Zone Temperature Environment:Isothermal jacket for cold space control Continuous P°monitoring |